Node will be stuck at "DXE--OOB Data Sync-Up” state while booting up
NX-3060-G5 Node will remain stuck at the Nutanix logo page while booting up and will show "DXE--OOB Data Sync-Up" in lower left corner of the screen
NX-3060-G5 node will remain stuck at the Nutanix logo page while booting up and will show "DXE--OOB Data Sync-Up" in lower left corner of the screen: As seen from the image above, if you check the lower right corner of the screen, you will see that the post code it is stuck on is DXE Phase: 0xB2 - which means that t...
This issue is either related to the NIC cards present in the node or with the node itself. So, in order to resolve this issue, perform the following operations: Remove all NIC cards present in the node (i.e. 10 G NIC card and any add-on NIC card if present). If without NIC cards, node still cannot boot up, then replac...
""Verify all the services in CVM (Controller VM)
start and stop cluster services\t\t\tNote: \""cluster stop\"" will stop all cluster. It is a disruptive command not to be used on production cluster"": ""Removes VIB packages from the host""
null
null
null
}
null
null
null
null
KB16587
How to modify the Traefik access log verbosity in DKP
How to modify the Traefik access log verbosity in DKP
By default Traefik access log level is set to WARNING. When troubleshooting access issues, for instance access to the DKP dashboard, the operator may need to increase the verbosity in Traefik logs so in this article we explain how to achieve this in DKP.
The Traefik default configuration is stored in the configmap “traefik-10.30.1-d2iq-defaults”. (note that the specific version numbers may change depending on the DKP version). To override the default configuration, we should first identify which configmap should be modified with the values we’re looking to change. To ...
KB7099
Explanation on reserved Space usage on ESXi Clusters due to thick provisioning
This KB explains how ESXi thick-provisioning results in reserved space at Nutanix side, including practical examples and interaction with snapshots.
In environments running ESXi, the users might see a "reserved space usage" higher than expected in the capacity planning view in Prism Central:Storage container at the same moment shows zero "Explicit reservation" - which can be configured manually in Prism/NCLI: ncli ctr ls | egrep "Name|Reservation"
As cluster is running ESXi, some VMs could have thick-provisioned disks since Nutanix does support Thick provisioning on NFS. Note: AHV uses iSCSI connections for VM disk access and does not support thick provisioning. To give an example of the amount being thick-provisioned, Prism displays the following: You can see ...
KB5893
How to check Power Consumption of each node
This KB documents the procedure to check the power consumption of each node
Currently, we can't see the Power consumption of each node from Prism but we can get these stats using Ipmitool commands because each IPMI interface would be able to show/collect this info.
The NX platforms do have this information presented and can be pulled via ipmi SDR/sensor command. In our testing, the granularity of the measurement was not small enough, and not accurately reflected when compared to the power supply reading for multi-node systems. These readings do not include power consumed by backp...
KB13574
Invalid msp-registry record in /etc/hosts on PCVM could affect IAMv2 pods during PCVM upgrade
Invalid msp-registry record in /etc/hosts file on PCVM node could affect IAMv2 pods during PCVM upgrade.
Invalid msp-registry record in /etc/hosts file on PCVM node could affect IAMv2 pods during PCVM upgrade.When this problem is observed, IAMv2 pods images pull may fail on the affected PCVM node, and pods may be stuck in ImagePullBackOff state. Note: CMSP upgrade and IAMv2 pods could fail due to multiple various issues;...
Workaround:As a workaround to this issue, the registry IP in /etc/hosts on the affected PCVM identified in steps 1 and 2 in the Description section needs to be changed to point to the correct PCVM.Considering the sample above we need to change /etc/hosts file on PCVM xx-xx-xx.43Using the vi command on xx-xx-xx.43 to up...
KB11962
Prism Element GUI throws console error when trying to configure RDMA network
Prism Element GUI throws console error when trying to configure RDMA network
When trying to configure RDMA network from the Prism UI, the configure window is stuck at "Loading" You may notice similar error as below in Chrome Developers Tools. lib.js?uiv=1612565316743:16 19:13:22 nutanix.ui.AppManager: Environment: PE Prism gateway logs shows up the below information during the time of e...
As per ENG-240241 https://jira.nutanix.com/browse/ENG-240241, this scenario is observed when there is an issue with fetching network information from backend service (caused due to vCenter not being registered in Prism for an ESXi cluster, acropolis service crashing in an AHV cluster, etc). ENG-416252 https://jira....
KB13359
Drive letters changed during the failover of VM in cross Hypervisor DR
This KB describes how to avoid the drive letter change during the failover of the VM in Cross Hypervisor DR
Drive letters are changed during the failover of the Windows VM in Cross Hypervisor DR Scenario:During cross hypervisor DR ( AHV -> ESXI ) or ( ESXI -> AHV ) If the CD ROM is assigned with the drive letter apart from D:/, may be E:/ or G:/ etc When the SAN policy within the OS is set to Offline Shared and the drive ...
Need to change the SAN (Storage area network) policy within the Windows VM in order to avoid the drive letter change even if the CD ROM is assigned with different Drive letter apart from D:\ during the failover operation in Cross hypervisor DRThe steps to follow to change the SAN policy within the Windows VM are:1. Lau...
KB12548
NCC Health Check: attached_vm_volume_different_recovery_clusters_check
The NCC Health Check: directly_attached_vg_vm_replication_to_different_clusters_check introduced in NCC 4.6 verifies if VM(s) with directly attached Volume Group(s) specified in Recovery Plan have their latest recovery points on the same cluster.
The NCC Health Check: directly_attached_vg_vm_replication_to_different_clusters_check introduced in NCC 4.6 checks if VM(s) with directly attached Volume Group(s) are replicated to different recovery clusters. Running NCC CheckThis check can be run as part of a complete NCC health check: nutanix@cvm$ ncc health_che...
Resolving this issue:Ensure that the VM(s) and directly attached Volume Group(s) listed in the alert have their latest recovery points on the same cluster. Refer to VM Recovery Points https://portal.nutanix.com/page/documents/details?targetId=Disaster-Recovery-DRaaS-Guide:ecd-ecdr-recoverypoints-ui-pc-r.html section ...
KB4784
CVM in reboot loop during AOS upgrade
CVM stuck in reboot loop during AOS upgrade
We have faced a situation where CVM is stuck in reboot loop during AOS upgrade & vmware logs has following signatures : 2017-09-13T12:58:39.528Z| vcpu-5| I125: Beginning monitor coredump This issue happens when memory assigned to virtual machine does not align with NUMA configuration on node.
This issue is described in VMware KB 10213 https://kb.vmware.com/s/article/10213. Get the VM ID of the CVM: vim-cmd vmsvc/getallvms Power off the CVM from ESXi command line: vim-cmd vmsvc/power.off <vm_id> Reference: VMware KB: Powering on a virtual machine from the command line when the host cannot be managed...
KB9231
NX Hardware [Memory] – Incorrect amount of memory displayed in Prism due to unsupported DIMM placement
Incorrect amount of memory displayed in Prism / host CLI because DIMMs were in the wrong slots.
This KB describes a scenario where Prism will incorrectly display a higher amount of memory on one or more nodes than the one installed in the system.NOTE: The identification section of this KB focuses on AHV as this was the hypervisor where this behaviour was observed first. Consider expanding the KB if this is found ...
Work with the customer to reseat the DIMMs to the proper slots as per the hardware configuration guide corresponding to the model ( Example link for 1065-G6 http://portal.nutanix.com/page/documents/list?type=hardware&filterKey=Component&filterVal=Memory) . Consider involving the account team to understand why the sl...
KB3309
Foundation fails with error: 'Block ID' cannot contain non-alphanumeric characters except '-' and '_' after chassis replacement.
Foundation fails with error "'Block ID' cannot contain non-alphanumeric characters except '-' and '_'" after chassis replacement.
Foundation may fail with following error in log and leave node in phoenix prompt: 20160501 07:56:11 INFO Running Phoenix20160501 07:56:22 INFO INFO: Running updated Phoenix20160501 07:56:22 INFO INFO: Model detected: NX-1065-G420160501 07:56:22 INFO INFO: Using node_serial from FRU20160501 07:56:22 INFO INFO: Using bl...
This can happen after chassis replacement is performed and for some reason, those fields were not filled in the factory.For Foundation to succeed, we only need to fill in "System S/N", which can be found on the sticker attached to the chassis.Please run following command to set S/N: ipmicfg-linux.x86_64 -tp systemsn ...
KB9523
Duplicate Zookeeper Processes running on CVM
Multiple Zookeeper processes running on a single CVM can lead to cluster wide service degradation and/or downtime.
Under normal conditions whenever zookeeper_monitor QFATALs or segfaults it will terminate the local Zookeeper server process and spawn a new Zookeeper server process. In certain conditions where access to /tmp on the CVM’s local filesystem is impacted zookeeper_monitor will not be able to kill the current Zookeeper pro...
Cause: This condition was seen in ONCALL-8875, ONCALL-8906, ONCALL-8701, and ONCALL-6876 along with an epoch and zkid mismatch. ENG-186817 https://jira.nutanix.com/browse/ENG-186817 addressed this issue since AOS 5.10.11 and 5.11+Previously whenever zookeeper_monitor would QFATAL or segfault it would terminate and rest...
{
null
null
null
null
Stargate.INFOFor a disk that fails during runtime
Stargate will be the first to notice any I/O problems. If Stargate finds that it takes more than 10 seconds* to finish a read or write operation to a particular SSD/NVMe drive
it will log a “hung op” and the drive will be marked offline.*This is the threshold for AOS 5.20.5+ and 6.1.2+. In earlier AOS releases
Stargate encounters a hang in write/read operation it had sent to the NVMe disk with Logical ID 1361406410 (check zeus_config_printer or “panacea_cli show_disk_list” for a mapping of disk serial numbers to logical Disk IDs).
the threshold is 40 seconds (ref ENG-428812 https://jira.nutanix.com/browse/ENG-428812).In the example below
KB15523
File Analytics - Elastic Search docker container stuck at starting state
Analytics_ES1 docker shows unhealthy due to container stuck in starting status
You may see the below alert being triggered In Prism Element."One or more components of the File Analytics VM xx.xx.xx.xx are not functioning properly or have failed"1. Verify the container for ES1 status using 'docker ps -a' and it will show as Unhelathy. [nutanix@NTNX-10-91-xx-xx-FAVM ~]$ docker ps -a 2. Verify the R...
Verify the FAVM configuration in PE as this problem generated due to insufficient memory configured for File Analytics VM.Follow the below guide and configure the correct required Memory and vCPU for the FAVM. File Analytics System Limits https://portal.nutanix.com/page/documents/details?targetId=Release-Notes-Analytic...
KB1961
Foundation hits a timeout when mounting hypervisor ISO
Foundation fails the imaging process at less than 10%. The node logs (from Foundation) show that Foundation is timing out when attempting to mount the hypervisor ISO.
Foundation fails the imaging process at less than 10%. The node logs (from Foundation) show that Foundation is timing out when attempting to mount the hypervisor ISO. 20150106 113329: IPMI node IP: 155.xx.xx.87
Verify that the SMCIPMITool can access the nodes BMC interface by using the following command from the Foundation VM. This verifies that the necessary ports are open. Follow KB-8889 https://portal.nutanix.com/kb/8889 on how to leverage SMC folders in various Foundation versions. [nutanix@nutanix-installer ~]# cd /home...
KB12498
Container latency wrongly displayed in Prism
In some cases container latency might be displayed in very high numbers in Prism and those stats may be not correct
It has been seen that the latency for the storage containers in Prism suddenly goes up and stays at very high levels. At the same time, all the VMs are showing completely normal latencies and aren't experiencing any issues.The bandwidth and IOPS graphs are not showing any increase of the load and the workload remains t...
The workaround is to restart the arithmos service cluster-wide: allssh genesis stop arithmos; cluster start After that, the reporting goes back to the correct numbers immediately:
KB9915
Unable to take Application Consistent Snapshot(VSS) on Windows VM when Windows DLL is missing
Unable-to-take-Application-Consistent-Snapshot-VSS-on-Windows-VM-when-Windows-DLL-is-missing
If Windows DLL such as atl110.DLL is missing NGT fails to take application consistent snapshot.Windows application event logs show the following. Failed to register Nutanix VSS Software Provider. NGT guest_agent_service.log shows the following. 2020-06-28 10:50:47 ERROR C:\Program Files\Nutanix\python\bin\guest_agent_s...
Restore the missing alt110.DLL from backup.
KB5541
Nutanix Files - Updating the AD Machine Account Password
The purpose of this article is to instruct the end-user how to properly update the Nutanix Files Machine Account Password.
In some cases, it is possible that the stored machine account password for the File Server can be lost or corrupted internally on the FSVMs. While this is rare, it will prevent the File Server from authenticating with Active Directory. Another, more likely scenario, is that an AD Administrator updated the Nutanix Files...
To correct this condition, you will need to update the machine account password for the File Server in both Active Directory and the File Server. To do this, first identify the File Server that you plan to update the machine account password. You can use the following 'ncli' command from any CVM to find this: nutanix@...
KB9210
Sudden increase in space utilization in clusters using NearSync data protection feature after PD transitions out of NearSync
This KB explains an issue with NearSync clusters that can result in an increase of space utilization under some error conditions, the workaround when encountered and the final resolution.
Note: This KB describes only one of the possible issues with leaked/stale snapshots on Nutanix clusters. There is a general KB about stale/leaked snapshots ( KB-12172 https://portal.nutanix.com/kb/12172) with reference to specific KBs for each different issue. Background As part of the NearSync workflow, there is a p...
Root Cause Initial implementation of Near sync on-demand PD hydrations and auto promote in Mesos layer only had a fixed number of retries for attempts to clear temporary files created in the LSW staging area. In some cases, certain error conditions led to the retries being exhausted, and the files leftover and manual ...
}
null
null
null
null
KB1876
NCC Health Check: disk_id_duplicate_check
The NCC health check disk_id_duplicate_check checks for duplicate disk IDs.
The NCC health check disk_id_duplicate_check checks for duplicate disk IDs.This check was introduced in NCC 1.3 onwards.This check returns a FAIL if it is not able to fetch a disk ID. Running the NCC CheckYou can run this check as part of the complete NCC Health Checks : nutanix@cvm$ ncc health_checks run_all Or you...
If the NCC check reports duplicate disk IDs, there may be a problem with the cluster configuration that needs to be further investigated. Debugging the duplicate disk IDs check issue is complex and requires assistance from the support team to verify if this poses a potential problem. Following are the steps to log a ca...
KB10529
Nutanix Kubernetes Engine - How to configure email alerts for a Karbon kubernetes cluster
How to configure email alerts for a Karbon kubernetes cluster
Nutanix Kubernetes Engine (NKE) is formerly known as Karbon or Karbon Platform Services. The NKE clusters created via Karbon don't display the Prometheus alerts outside of the Karbon K8s cluster Alerts page.following are the steps to get email notifications for a Karbon created Kubernetes cluster Alerts until they are ...
To set up email alert notifications, the script below is going to update the config for the alertmanager secret and restart the pods running inside the Karbon ntnx-system namespace. Download the alertmanager_update http://download.nutanix.com/kbattachments/10529/alertmanager_update.tar.gz script to a Linux machine. Do...
KB7356
LCM SATADOM upgrade failed with 'ata4: COMRESET failed (errno=-16)' error
LCM SATADOM upgrade failed with 'ata4: COMRESET failed (errno=-16)' error
Problem:This KB was submitted in order to track and analyze a new issue experienced during the SATADOM upgrade via LCM, from the FW version S560301N to higher versions, such as S670330N. As per ISB-090 https://docs.google.com/document/d/1xRYEshe-frshD9aBz73MNBroRZyuIxFkY-xk5Qg37OQ/edit#heading=h.4z6t03g9lz4g, satadoms...
Gather the following info, then reboot the node to Phoenix again. Attempt to run python phoenix/reboot_to_host.py and see if the SATADOM comes back.Raise a new ENG if it's still unresponsive and reference that you tried to apply the contents of the KB.1. Collect the output of commands on the SATADOM device, e.g. /dev/s...
KB16620
Why is Chartmuseum stuck in Pending State?
Why is Chartmuseum stuck in Pending State?
When deploying Kommander in a cluster deployed with the DKP vSphere provider, some users have reported that chartmuseum gets stuck in pending state. In some cases, when describing the pod, it becomes evident that the chartmuseum persistent volume claim (PVC) is in pending status: kubectl -n kommander get pv,pvc ...
To confirm whether this is the cause of chartmuseum being stuck, please describe the PVC with name chartmuseum and look in the events whether the controller is having issue login in to the vCenter, example shown below: kubectl -n kommander describe pvc chartmuseum Name: chartmuseumNamespace: ...
KB6848
NX Hardware [Memory] – Memory showing incorrect size rather than the real physical size
null
Memory "M393A4K40BB0-CPB" is showing as 16384 MB in IPMI console when it should be 32768 MB. NCC check ipmi_sensor_threshold_check returns the following: Node x.x.x.x: NCC plugin show_hardware_info shows memory size is different than others: nutanix@cvm$ ncc hardware_info show_hardware_info Get the DIMM hardware ...
Get the real size of the product by part number "M393A4K40BB0-CPB" from Google or SFDC. It is "C/X-MEM-32GB-DDR4-R".Dispatch new DIMM for replacement.For more information on DIMM replacement, check KB 3703 https://portal.nutanix.com/kb/3703.
KB11322
NCC Health Check: disk_configuration_vs_intent_consistency_check
The NCC health check plugin disk_configuration_vs_intent_consistency_check reports whether SED disk configuration in zeus is consistent with the intent in regard to different states of SED protection and KMS server availability.
The NCC health check plugin disk_configuration_vs_intent_consistency_check reports whether SED disk configuration in zeus is consistent with the intent in regard to different states of SED protection and Key Management Server (KMS) availability.For more information on Data-at-Rest encryption with SED, see Nutanix Secu...
CAUTION: Do not perform any upgrades, CVM, node reboot, or HW maintenance before resolving this issue.Consider engaging Nutanix Support https://portal.nutanix.com/
KB3621
How to import an OVA image to AHV cluster
From AOS 5.18, OVA files can be natively imported and exported through Prism Central. This article provides manual steps to complete the task.
From AOS 5.18, OVA files can be natively imported and exported through Prism Central. Refer to the OVA Management https://portal.nutanix.com/page/documents/details?targetId=Prism-Central-Guide-vpc:mul-ova-manage-pc-c.html chapter of the Prism Central Infrastructure Guide. For manual steps, proceed with the solution se...
Manual stepsThe following figure summarises the steps to create a new VM from an OVA file. Pre-requisite for moving Linux VMs/Windows VMs from ESXi to AHV Install VirtIO Drivers from the following: Migration Guide: Migrating Linux VMs from ESXi to AHV https://portal.nutanix.com/page/documents/details?targetId=Mig...
KB17134
NDB - SSH Keys for era & erauser not renewed for more than 1 year leading to a critical security risk
SSH Keys for era & erauser not renewed for more than 1 year leading to a critical security risk.
NDB requires the end-user to register a valid SSH key while provisioning a DB server VM from the NDB WebUI as part of the automation provisioning process. This feature enables the end-user to connect to the provisioned DBVM via SSH from their application.However, once the SSH keys have not been renewed for more than 1 ...
As a short term workaround, delete the contents of the authorized_keys file: .ssh/authorized_keys.Note: Please backup the file before deleting its contents as a precaution.
KB5618
CVM lost networking in VMWare ESXi after changing VMKernel settings
CVM was not reachable to other CVMs and services did not come online after changing VMKernel settings
CVM was not ping reachable to other CVMs and services did not come online after changing VMKernel settings. Affected CVM might show in genesis.log with this message 2018-05-22 15:25:07 INFO ipv4config.py:841 Discovered network information: hwaddr 00:0c:29:f6:d0:57, address 10.XX.X.118, netmask 255.255.254.0, gateway 1...
This is known VMWare bug, but no fix other than workaroundOriginal setting of Network Adapter 1, checked for connected and connect at power on configuration for original port group named "public" (can be anything). Click OKDisconnect and change the network label to different network label "Backplane Network" (Can be an...
KB16091
How to set a Delegate Approver
null
Guide on Delegate Approver set in SFDC including1. FAQ2. Steps to Assigning a Delegate Approver3. how to Enabling Delegate Approver Email notifications
For more information, click here https://docs.google.com/document/d/1cdCOC8jtTbV9T6LbKOB4PM-x1JrhQ3706HsTe221REc/edit#heading=h.o4lalfpvhxq.Point of contact: hemanth.kumar@nutanix.com
KB5594
Alert - A1092 - Unsupported Configuration For Redundancy Factor 3
This article describes the steps for troubleshooting an Alert A1092.
This KB describes how to troubleshoot the alert A1092 - unsupported configuration for redundancy factor 3 (UnsupportedConfigurationForFT2).For an overview on alerts and whom to contact when an alert case is raised, see KB 1959 https://portal.nutanix.com/kb/1959. Alert Overview The unsupported configuration for redun...
The AOS Web Console Guide https://portal.nutanix.com/page/documents/details?targetId=Web-Console-Guide-Prism:arc-redundancy-factor3-c.html describes the Redundancy Factor 3 feature and requirements. The Acropolis Advanced Administration Guide https://portal.nutanix.com/page/documents/details?targetId=Advanced-Ad...
KB13909
Domain fault tolerance for Oplog component in Prism periodically flips between 1 and 2
Oplog fault tolerance can flip between 1 and 2 when a container RF was increased after cluster creation.
This issue can be seen on clusters with Redundancy Factor 3 and Fault Tolerance 2 which were initially created as FT 1 and Redundancy Factor 2 and then converted.Customers may notice that the "Data Resiliency Status" is not OK due to the Oplog component fault tolerance flipping between 1 and 2 periodically.Note: This h...
This behavior happens as the counters vdisks are created soon after the cluster is created and with a static oplog replication_factor in vdisk config that matches the replication factor of NutanixManagementShare container. And if a cluster was created as RF2(FT1) and later changed to RF3(FT2) the static oplog override...
KB1484
HW: NX GPU Troubleshooting (ESXi)
Troubleshooting GPU based issues on ESXi Hypervisor
Certain NX series nodes can be configured with one or two Nvidia GPU cards that allow video rendering to be passed through to VMs. This document is meant to assist with troubleshooting issues related to GPU functionality. Additional documentation: NVIDIA vGPU on Nutanix. https://portal.nutanix.com/page/documents/solut...
There are four ways to configure video rendering for use with VMs in ESXi. Soft 3d -- Software-based 3d rendering. It uses CPU for rendering and is slower than GPU.sVGA -- GPU-based rendering. Multiple GPUs can be shared across multiple virtual machines.dVGA -- GPU-based rendering. A single GPU is directly passed throu...
2023-06-05T10:58:45.205804-05:00 NTNX-22SH6M300266-C-CVM kernel: [ 1312.270764] vmd 0000:13:00.0: PCI_INTERRUPT_LINE read is non zero 0xff[
null
null
null
null
""Latest Firmware"": ""14.27.1016""
null
null
null
null
KB6854
Linux Boot Error - NetworkManager System Settings was not provided by any .service files - Move
Linux Boot Error - NetworkManager System Settings was not provided by any .service files - Move
After Move migrated a Linux VM to AHV it was booting up hanging with the following error process 1788: WARNING **: get_all_cb: couldn't retrieve system settings properties: (2) The name org.freedesktop.NetworkManager System Settings was not provided by any .service files
To resolve the issue on the AHV side Booted into single user mode on the VM Ran the following commands to uninstall NetworkManager #service NetworkManager stop To remove NetworkManager without removing dependencies ( DO NOT REMOVE DEPENDENCIES) , use rpm methodTo list the NETWORKMANAGER packages run the following c...
KB12194
Unreferenced Nutanix Disaster Recovery snapshots taking up space
This article describes an issue where unreferenced Nutanix Disaster Recovery snapshots are taking up space.
NOTES: This KB is part of KB 12172 - Stale/leaked snapshots in Nutanix http://portal.nutanix.com/kb/12172. If the symptoms below do not apply, verify the content of the main KB for a different match.Nutanix Disaster Recovery (DR) was formerly known as Leap. When changing from Nutanix DR Nearsync to syncrep or async ...
A TH is required to clean up the unreferenced snapshots on Cerebro using specific scripts. If the snapshots are not too old, collect a log bundle and open an ENG ticket for RCA.
KB8460
Alert- A130174 - RecoveryPointReplicationFailed
Investigating RecoveryPointReplicationFailure issues on a Nutanix cluster
This Nutanix article provides the information required for troubleshooting the alert RecoveryPointReplicationFailed for your Nutanix cluster. Alert Overview After configuring the categories and protection policies on the on-prem PC (Prism Central), if the network connectivity is not normal between the on-prem PC and ...
Troubleshooting and Resolving the IssueFor both on-prem and Xi-Leap use cases, gather log bundles on both Prism Central and the Prism Element cluster hosting the affected VM. See "Collecting Additional Information". If the target availability zone is an on-prem PC, verify network connectivity between the local on-prem...
KB12902
Nutanix Files: Smart DR failing to manage SPNs during failover
Smart DR fails to manage SPNs when NFS and SMB are using AD as a Directory Service
During Smart DR failovers the SPNs for the source Nutanix Files server is deleted under the source Nutanix Files machine account and then are added under the machine account of the target Nutanix Files server. The result will look like the below.Source Nutanix Files machine account: No SPNs Target Nutanix Files machin...
This issue is scoped to be resolved in Nutanix Files 4.1, 4.2, and 4.0.3.Below are the two workarounds for this issue.1) Change the Directory Service for NFS.If there are no NFS exports on Nutnaix Files using Kerbose authentication, you can change the Directory Service to unmanaged or LDAP. If there are no NFS exports...
KB10134
File Analytics Deployment Fails Due To Network Communication Issues Between FAVM and CVMs
Nutanix Files Analytics cannot be deployed due to no communication between Files Analytics VM and CVM network.
Issue 1: deploying File Analytics fails with the below error: Cannot connect to File Analytics VM from Prism. Please verify that network details for the VM are correct and the IP is reachable from Prism. This issue occurs when the FAVM's IP is unreachable via the CVMs network. The File Analytics Guide: Deployment Re...
Solution1: Use the below to identify the Prism leader CVM: nutanix@CVM:~$ curl localhost:2019/prism/leader && echo Open an SSH session to the Prism leader CVM. Run the below to tail the prism_gateway.log on the Prism leader CVM: nutanix@CVM:~$ tail -F /home/nutanix/data/logs/prism_gateway.log | grep Analytics No...
}
null
null
null
null
KB13484
HPE CVM fails to power on with error message "unexpected exit status 1: [Errno 2] No such file or directory: '/sys/bus/pci/devices/0000:85:05.5/driver_override'"
If an HPE host with NVMe drives has its motherboard replaced, it may need the Intel VMD (Volume Management Device) enabled in the BIOS before the Controller VM (CVM) can see the RAID controller.
When trying to boot the Controller VM (CVM) on an HPe node, it may fail to complete the boot giving the error: [root@AHV ~]# virsh start NTNX-xxxxxx-CVM This implies that the device at the PCI bus address 85:05.5 is absent. [root@AHV ~]# lspci | grep -i 'RAID bus controller' No devices were seen. Confirm that the ...
Enable Intel VMD in the BIOS. Create the following JSON file called vmdupdate.json: { Apply via the ilorest utility: [root@AHV ~]# ilorest After the host restarts, confirm that the CVM has now completed booting.The host should be able to see the RAID controller as well. [root@AHV ~]# lspci | grep -i 'RAID bus con...
KB4069
vlog : gflag verbose logging option
Enable gflag vlog if you need verbose logging. Ask senior SRE or escalation engineer before enable it. Verbose logging requires a lot of care.
Sometimes the default logging level doesn't tell us enough info as to why the Cluster/CVM is hitting the particular issue. Verbose logging (vlog) generates lots of logs at .INFO log level.
WARNING: Support, SEs and Partners should never make Zeus, Zookeeper or Gflag alterations without review and verification by any ONCALL screener or Dev-Ex Team member. Consult with an ONCALL screener or Dev-Ex Team member before doing any of these changes. See the Zeus Config & GFLAG Editing Guidelines https://docs.go...
""Latest Firmware"": ""0x80004cdb""
null
null
null
null
KB1437
Troubleshooting the Remote Site Replication Error Message "StartReplicationRPC to remote X failed with error kStaleCluster"
The following error message is displayed in Prism: Protection domain <Protection Domain 1> replication to remote site <Remote Site 1> failed. StartReplication RPC to remote <Remote Site 1> failed with error kStaleCluster
The following error message is displayed in Prism: Protection domain <Protection Domain 1> replication to remote site <Remote Site 1> failed. StartReplication RPC to remote <Remote Site 1> failed with error kStaleCluster
The error message can occur in a disaster recovery or backup configuration where: A mirror backup site is not configured in the remote site, which is a requirement for remote replication to work.You destroyed a remote cluster and recreated it, but the local site still references the IP address of this cluster. The wo...
KB2219
NCC Health Check: check_cvm_configuration
The NCC health check "check_cvm_configuration" verifies the CVM configuration. This check is relevant only to Nutanix clusters running the Microsoft Hyper-V hypervisors.
The NCC health check check_cvm_configuration verifies a series of configurations and best practices that need to be in place for the Controller VMs (CVMs). Note: This check runs only on Nutanix clusters running the Microsoft Hyper-V hypervisor. This check verifies the following aspects of the Controller VMs configura...
Before running the Repair-CVM command, see Instructions on running Repair-CVM on Hyper-V https://portal.nutanix.com/kb/1725 (if required for the resolution of any of these issues) as the Controller VM is rebooted after running this command and the cluster should be able to tolerate a node down or failure before the Co...
KB14707
Time skew between PE and PC causes MSP enable failure due to registry became unavailable during MSP deployment
Time skew causes MSP enable failure due to registry became unavailable during MSP deployment
If an MSP platform is enabled on scale-out Prism Central, an internal docker registry is deployed on two of the PCVM nodes to support the deployment of PCVM MSP services.Internally, the registry and MSP controller use a connection to the Prism Element to store its data there. To handle registry service failover between...
Check for NTP-sync issues inside PE or between PC and PE and resolve the issue. Refer to KB-4519 http://portal.nutanix.com/kb/4519 for time sync troubleshooting.Once NTP is in sync GetVersions() should not fail, and MSP enablement should complete successfully.
KB12454
Cluster Expand - Guidance to add a node to Nutanix cluster with VMware NSX-T setup
This KB covers a scenario of Cluster Expand - Adding a node to Nutanix cluster after configuring for VMware NSX which is not supported and expand operation will fail at pre-check Errors:Failed to get VLAN tag of node
In VMware setups using NSX-T, performing a cluster expand operation may fail with the below error in Prism.In the error, we will see the IPV6 address of the new node eth0 interface. Errors: Failed to get VLAN tag of node" fe80::xxx:xxxx:xxxx:e23a%eth0 We can confirm by running discover_nodes from any of the existing n...
As per Infra Engineering team, Expanding a cluster with NSX-T is supported. However, we expect customers to configure NSX-T in vCenter only after adding the node to the cluster. Migrate the node networking to the NSX-T enabled configuration after the node gets added to the cluster.To avoid this scenario, Nutanix rec...
KB8608
Finding the serial ID of a bad HDD or SSD
null
When a bad HDD/SSD is present on a node, and foundation is performing the imaging of the node, it may fail with the following message: StandardError: Failed command: [/usr/bin/sg_inq /dev/sda] with reason [sg_inq: error opening file: /dev/sda: No such device or address] The following messages can be seen when the node ...
The disk serial can be identified by udevadm: udevadm info --query=all --name=/dev/sdX | grep ID_SERIAL As an example, if you want to find the serial ID of disk /dev/sda : $ udevadm info --query=all --name=/dev/sda | grep ID_SERIAL
KB9456
Alert - A400114 - PolicyEngineServiceDown
This Nutanix article provides the information required for troubleshooting the alert PolicyEngineServiceDown for your Nutanix cluster.
Nutanix Self-Service is formerly known as Calm. Alert Overview The PolicyEngineServiceDown alert is generated when any of the internal services of NuCalm Policy Engine is down. Sample Alert Block Serial Number: 16SMXXXXXXXX Output messaging [ { "400114": "Calm Policy Engine internal service is down", "C...
Troubleshooting and Resolving the Issue Check the status of Policy Engine VM from Prism Central UIVerify the status of Policy Engine service by running below commandsLog in to Policy Engine VM through ssh sessionRun the below command: docker ps Sample output: [nutanix@localhost ~]$ docker ps Confirm if the conta...
KB4114
NCC Health Check: mellanox_nic_status_check
The NCC health check mellanox_nic_status_check checks if Mellanox NICs are down or if any Mellanox NIC has speed other than 10GbE or 40GbE.
The NCC Health Check ncc health_checks network_checks mellanox_nic_status_check checks if Mellanox NICs are down or if any Mellanox NIC has a speed other than 10GbE or 40GbE. NOTE: If the cluster runs NCC version earlier than 3.0.3, upgrade to NCC 3.0.3, and re-run the above check. To find the NCC version running o...
If you have mixed NIC types (For example, Intel and Mellanox), the following warning appears when the Mellanox NIC type is not in use : WARN: All mellanox NICs on host machine are Down. To find the type of NICs you are using on the host, run the below command : nutanix@cvm$ ncc hardware_info show_hardware_info | awk '...
KB2007
Genesis Keeps Restarting: "Data disks are not clean"
A connection error message or connection timeout is observed if you open the Prism Central web console. Genesis restarts every few seconds.
A connection error message or connection timeout is observed if you open the Prism Central web console.Review of the cluster logs shows Genesis restarts every few seconds with an output similar to the following in genesis.out: 2015-01-16 10:06:38 ERROR node_manager.py:2935 Zookeeper mapping is unconfigured The same err...
Check the /etc/hosts file and verify the integrity of the line with the zookeper hostname.It should look like the following: 127.0.0.1 localhost localhost.localdomain localhost4 localhost4.localdomain4 It is important to ensure a single space between the IP and the zk entry. If there is anything else, like a tab or...
KB16050
Nutanix Self Service Policy Engine: LCM is unable to upgrade Calm Policy Engine version
A solution for the scenario where the Lcm is not able to finalize the Calm Policy Engine versions upgrade.
Nutanix Self-Service (NSS) is formerly known as Calm.Identification: The Lcm Inventory page on Prism Central will show the Policy Engine version available even after a successful upgrade was performed.Checking the ~/data/logs/nucalm.out log file we might notice that the calm is detecting the policy engine as a lower v...
During the LCM upgrade process, we noticed that container images are been upgraded however, the zk node is not getting updated with the correct version. To ensure you are hitting the same issue. These zk nodes need to be validated:NOTE: The command output should show two entries, comma-separated, one with the incorrect...
KB13981
LCM: BMC/BIOS upgrade failed with Error LcmActionsError: no node
LCM: BMC/BIOS upgrade failed with Error LcmActionsError: no node
LCM BMC / BIOS upgrade failed following which the affected host stuck in phoenixlcm_ops.out from LCM leader node 2022-11-15 03:33:38,006Z ERROR lcm_actions_helper.py:709 (x.x.x.x, kLcmUpdateOperation, 4321a8b0-fdca-455c-ab1f-79ee173d5bf4) Genesis logs Exception 'UpdateOp' object has no attribute '_filter_task' in __ch...
Restore the node from phoenix using KB 9437 https://portal.nutanix.com/kb/9437Refer to Debugging PhoRest-based Async Upgrade Failures KB 13023 http://portal.nutanix.com/kb/13023Restart genesis on the LCM leader node and retry the updateGenesis restart will re-start the LcmFramework on the node with the correct number...
KB7385
Hyper-V: Unable to boot VM after migrating protection domain to remote site on Hyper-V cluster
null
VM failing to boot with following error after migrating protection domain to remote site on Hyper-v 2012 R2 cluster Error (12711)
Run following command from SCVMM machine:1. Create a variable for problematic VM $vm = Get-scvirtualmachine -name “VM_Name” 2. Force a refresh refresh-vm -force $vm Or, from any other machine:1. Load the SCVMM cmdlets: Add-PSSnapin microsoft.systemcenter.virtualmachinemanager 2. Connect to the SCVMM server: Get-VMM...
KB7002
Nutanix Files - File Server Unreachable after upgrade from 2.x to 3.x
Minerva might crash due to having old snapshots (WPV) when migrating from 2.x to 3.x
CASE I: On upgrading to 3.x code from 2.x code, customer might see an unreachable on Prism for the File Server.The share access will be uninterrupted however you will see the following symptoms :1. Alert will be generated: ID : 926f2fbd-d206-4004-ad1d-c060e37f834b 2.Genesis.out of the F...
SOLUTION I: "WARNING: Support, SEs and Partners should never make Zeus, Zookeeper or Gflag alterations without guidance from Engineering or a Senior SRE. Consult with a Senior SRE or a Support Tech Lead (STL) before doing any of these changes. See the Zeus Config & GFLAG Editing Guidelines ( https://docs.google.com/do...
KB9101
Cluster Expansion fails with "Failed to ssh to node. Please check if keys are setup properly" or "Failed to fetch the memory of new CVM" or "Failed to fetch disks from the node"
The article explains why cluster Expansion fails with "Failed to ssh to node. Please check if keys are setup properly" or "Failed to fetch the memory of new CVM" or "Failed to fetch disks from the node" and how to work around the problem.
Scenario 1 Expand cluster operation fails with "Failed to ssh to node. Please check if keys are setup properly" error at 78%. Scenario 2 Expand cluster operation fails with "Failed to fetch the memory of new CVM x.x.x.x" error. The error appears in /home/nutanix/data/logs/genesis.out logs on the leader node. 202...
Before you proceed with the following steps to replace the non-default SSH key, verify that Expand cluster Prerequisites and Requirements https://portal.nutanix.com/page/documents/details?targetId=Web-Console-Guide-Prism-v6_1:wc-cluster-expand-wc-r.html are met.You can use the following steps to verify connectivity fr...
KB2893
Collecting diagnostic data during a ESXi PSOD or a Hung AHV Host
This article should be used for the collection of diagnostics logs and output for when a host goes down.
Collecting diagnostics data during an ESXi PSOD (purple diagnostic screen) or when an AHV Host is hung can provide valuable insight into why it happened. Even if the host has already come up, logs and command output can be collected to identify the cause.
As the default behavior of ESXi is to sit at the PSOD (purple diagnostic screen) our recommendation is to leave it in this downstate and open a support case so that the OOB script can be run against the host. The out-of-band script gathers a wide range of pre & post-data as well as runs diagnostic tests that can help p...
KB5012
[Performance] Interpreting CPU Ready values
High RDY values can be concerning, but they are subject to misinterpretation. This article is intended to help interpret CPU Ready values reported from various sources.
High CPU Ready values can be a sign of CPU contention, which can cause performance issues for many applications. It is important to consider the specific application impacted and its tolerance while interpreting these values, as some applications experience delays at values as low as 1%, and others can tolerate highe...
CPU Ready is the time a virtual CPU is ready to run but is not being scheduled on a physical CPU; this usually indicates that there is not enough physical CPU to schedule the work immediately. To be able to interpret ready times it is essential to know the relationship between the CPU ready time in percentage (%) and m...
KB14778
File Analytics - FA 3.2.1 may fail to start services after a reboot
This KB addresses resetting the expiration timer for the 'root' user password, which was preventing File Analytics services from starting.
Beginning in File Analytics (FA) 3.2.1, the root account password expiration is now set to 60 days.If you are running File Analytics 3.2.1, the password for the root account will expire after 60 days from the time of deployment or upgrade.File Analytics has a startup script that mounts the backing Volume Group where th...
This issue has been fixed in File Analytics 3.3.0.1 and later.If File Analytics 3.2.1 is currently unable to start services due to this issue, use the following workaround to reset the 60-day timer: SSH to the FAVMRun sudo chage -d <current date> root [nutanix@FAVM ~]$ sudo chage -d 2023-05-10 root This sets the "Las...
KB4710
Nutanix Files - Troubleshooting Kerberos authentication on a Nutanix Files server.
Nutanix Files - Troubleshooting Kerberos authentication on a Nutanix Files server.
The Nutanix Files server uses Kerberos authentication. The Kerberos version 5 authentication protocol provides a mechanism for authentication — and mutual authentication — between a client and a server, or between one server and another server.Important: This is a generic KB that is created to explain the basics and re...
If you are able to browse the share by IP and not the DNS name you are having a problem with Kerberos authentication. Most of the time it will be the one of the following which should be checked in order.1. Time2. DNS3. SPN4. Machine account There have been cases where following occurs Nutanix Files joined to AD doma...
KB8627
NX hardware health stresstest
null
There are instances when there can be no evidence of hardware faults in1. NCC health Checks2. IPMI SEL Logs3. Running SmartCtl on all the disk and SATADOMsBut there are evidence in Log files (dmesg , /home/log/messages or /var/log/messages) where you can see binary corruptions which point to HW issues.
Run a StressTest on the system components(CPU and memory) to see if there are any evidence of hardware issues:1. Upgrade to the latest BMC and BIOS version . You can use LCM or manually upgrade the host.2. Mount Regular Phoenix ISO on the affected server and reboot to it.3. Once in phoenix prompt , mount the Stressiso2...
KB10011
Objects - Read failures due to object controller pods crashing with "Check failed: data endpoint=x.y.z:2009"
Customer on AOS 5.18/5.18.0.5 may report read issues. Further investigation finds that OC pods are crashing with signature: "Check failed: data endpoint=x.y.z:2009"
Customers on AOS 5.18/5.18.0.5 may report object store READ issues. Further investigation finds that object controller pods are crashing with signature: F0909 15:45:55.066007 3945 storage_endpoint.cc:237] Check failed: data endpoint=a.b.c.d:2009 Symptoms: Customer reporting issues reading from the object cluster. T...
This issue is resolved in AOS 5.18.1 and higher. Please upgrade the AOS cluster to version 5.18.1 or higher.
KB12533
Nutanix Files - Single node FSVM cluster failed to activate File Server
File server activation in DR fails after a Protection Domain migration.
After migration of a Protection Domain to the DR site, you see the following Prism alert: File Server activation failed A160021 warning : A stand-alone File server fails to activate on the DR site.In Minerva leader (Follow KB-4355 https://portal.nutanix.com/page/documents/kbs/details?targetId=kA032000000TWV5CAO to f...
This issue is resolved in Nutanix Files 4.0. Upgrade File server to the latest supported version.
}
null
null
null
null
KB8880
Understanding 3rd Party Backup Integration
3rd Party Backup integration is explained for different hypervisors
This article gives a brief overview of 3rd party backup integration used on a Nutanix cluster. Nutanix supports integration of 3rd party backup software on clusters running AHV, ESXi and Hyper-V.The integration on these hypervisor differ from each other. The key differences are mentioned below: AHV Leverages a particul...
If any issues occur while using 3rd party backup software, please engage Nutanix Support for further assistance and have the following information available: Backup software vendorHypervisor versionAOS versionNCC versionNumber of backups jobs / schedule
KB6970
PE-PC Connection Failure alerts
PE-PC Connection failure alerts are being generated and not auto resolved. Verify underlying connectivity, upgrade NCC, and re-set the check.
Scenario 1. "PE-PC Connection Failure" while no underlying issue with PE (Prism Element) - PC (Prism Central) connectivity. nutanix@CVM$ ncli alert ls Scenario 2. PE - PC connectivity checks return red heart even if there are no alerts or underlying conditions present. If PE - PC connectivity checks fail for brief p...
Note: If you are having issues either enabling or disabling this check after the NCC upgrade, this behaviour is fixed in NCC 3.10.1 and above. Upgrade to the latest NCC. Scenario 1. The auto resolution of this alert is improved in NCC 3.9.4 or later. To resolve this issue, upgrade NCC to the latest. In addition, aler...
KB17129
License missing on Support Portal
When a license is valid and available in SFDC but not reflecting in Support portal
When customer contact us stating the license is purchased but not reflecting in Support Portal
null
KB17053
VM with APC (Advanced Processor Compatibility) fails to be created or Live migrate between clusters
When attempting to create a VM or CCLM (Cross Cluster Live Migration) with the new AOS 6.8.x APC (Advanced Processor Compatibility) feature, an error might be seen indicating that the destination cluster does not support the VM’s CPU model.
Scenario 1 When attempting a CCLM (Cross Cluster Live Migration) with the new APC (Advanced Processor Compatibility) set to a supported level for both the source and the destination cluster, the validation may fail with the following error: Cannot migrate VM with UUID <UUID> because target cluster with UUID <UUID> do...
This is currently a known race condition between AHV Gateway, EMM and libvirt - ENG-666516 https://jira.nutanix.com/browse/ENG-666516This only occurs on clusters that were upgraded to AOS 6.8.WorkaroundPerform the following actions to apply a workaround: Ensure that the selected APC level is supported by the nodes on ...
KB6591
NCC Health Check: recovery_plan_multiple_az_order_check
NCC 3.7.1. The NCC health check recovery_plan_multiple_az_order_check raises an alert if VMs replicated to different Availability Zones are part of the same recovery plan.
Note: This health check is retired in NCC 5.0.0 and later. Ensure you are running the latest version of NCC before running the NCC health checks. The NCC check recovery_plan_multiple_az_order_check verifies and raises an alert if VMs replicated to different Availability Zones are part of the same recovery plan. This ...
Update the Protection Policies for the entities in the recovery plan so that they replicate into the same Destination Availability Zones.
KB12179
Windows 11 support on AHV
Is Windows 11 supported on AHV?
Is Windows 11 supported on AHV?
Windows 11 requires Trusted Platform Module (TPM) version 2.0, which is supported starting from AOS 6.5.1 with AHV 20220304.242. Note that 20220304.242 is an optional upgrade path, and by default, AOS 6.5.1 is bundled with AHV 20201105.30411. Refer to Securing AHV VMs with Virtual Trusted Platform Module (vTPM) https:...
KB4085
Troubleshooting Network Visualization on AHV cluster
Tips for investigating issues with Network Visualization setup on an AHV cluster.
Cluster Network Visualization is a feature first added in AOS 5.0 which visually displays network paths up to the immediate switches. The network visualization configuration requires the user to add the switch details in Prism Element (Settings / Network Switch). Network visualization uses SNMP to get statistical infor...
The network visualizer display will add an "Unknown Switch" for any ports at the AHV host side that it cannot associate with discovered ports from the switch side. All ports without discovered switch information to match will show linked to this "Unknown Switch". Switches that are added successfully in Prism will show...
KB9550
1-Click ESXi Upgrade stuck at 14% due to missing locker symlink
1-Click ESXi upgrade stuck at 14% as underlying ESXi upgrade fails to load files on locker directory
Issue1-Click ESXi upgrade stuck at 14% due to missing /locker symlink on ESXi hosts.Symptoms Host upgrade would be stuck at 14%host_upgrade_status would show “Host upgrade failed during previous run” for host nutanix@CVM:~$ host_upgrade_status CauseWe'll see in the vobd.log the host has entered and exited the maint...
1) From the CVM, SSH into the host that does not have the /locker softlink to /store. nutanix@CVM:~$ ssh root@<IP of host> 2) Make sure you are in root directory. [root@ESXi:~] cd / 3) Make a backup of the /locker directory. [root@ESXi:~] mv /locker /locker.old 4) Create the /locker symlink to the /store directory. ...
KB4818
Nutanix Move (Data Mover): Migrating VMs having both IDE and SCSI disks
This article describes how to migrate VMs having both IDE and SCSI disks using Nutanix Move.
If VM has a combination of IDE and SCSI Bus type disks, and if BOOT disk is on IDE Bus type, then we might see performance issues after migrating such VMs to AHV. Nutanix Move cannot determine the Bus type of the disks (whether it is SCSI or IDE) at source ESXi. This can lead to performance issues after migrating VMs ...
If you are observing performance issues after migrating such VMs to AHV, then you need to convert the IDE Bus type BOOT disk to SCSI Bus type disk and then boot the VM again. Follow KB 8062 http://portal.nutanix.com/kb/8062 to convert IDE Bus type disk to SCSI Bus type disk.
KB7785
LCM: Pre-check failure "test_catalog_workflows".
LCM: Pre-check failure "test_catalog_workflows".
During an LCM (Life Cycle Manager) inventory operation, the LCM framework downloads required modules and files from Nutanix servers with the help of the Catalog service. If the download operation is not successful, the LCM pre-check "test_catalog_workflows" fails. Operation failed. Reason: Lcm prechecks detected 1 is...
Log in to a CVM (Controller VM) via ssh and identity the LCM leader using the following command: nutanix@cvm$ lcm_leader SSH to the LCM leader and check lcm_wget.logs: nutanix@cvm$ less /home/nutanix/data/logs/lcm_wget.log If you see any issue in that log file, check your connection from the CVM to the Internet and...
KB15024
Selective vdisk usage scan timeout after AOS upgrade
Selective vdisk usage scans might repetitively fail due to timeout after AOS upgrade to version 6.5.2 and above.
PE clusters after upgrade to AOS versions 6.5.2 or 6.6 and above (containing the fix for ENG-422034) are susceptible to an issue described below. The one-time Selective Vdisk Usage (SVDU) Curator scan is triggered post-upgrade in order to fix the inherited_user_bytes calculation, that was causing discrepancy between a...
WARNING: Support, SEs and Partners should never make Zeus, Zookeeper or Gflag alterations without review and verification by any ONCALL screener or Dev-Ex Team member. Consult with an ONCALL screener or Dev-Ex Team member before doing any of these changes. See the Zeus Config & GFLAG Editing Guidelines https://docs.go...
KB12691
"NIC link down" alert for Internal USB device interface raised due to LCM inventory
The KB provides you troubleshooting steps to understand and verify if you are facing the issue.
The NCC health check nic_link_down_check verifies if the configured host NICs have a UP link status, refer KB http://portal.nutanix.com/kb/2480 2480 http://portal.nutanix.com/kb/2480 for further details on the check. With NCC versions prior to 4.5.0.2 or 4.6.0 we have observed that an alert or warning message in NCC ...
If enp******* USB-NIC link status is False and you receive the nic down alert: Please upgrade NCC to 4.5.0.2+ or NCC 4.6.0+. The USB interface is ignored in versions beyond 4.5.0.2+ and 4.6.0+ because it is only utilized during specific inventory and upgrade operations and its state is expected to vary because of that....
KB13098
Nutanix Files -- SMBD service crashes may cause TDB database bloat
SMBD service crashes there could be tdb database overflow
In Nutanix Files 3.8.x and 4.0 when the SMBD service crashes or restarts for any reason including, unplanned Host outages the TDB database can bloat. Some of the symptoms of this issue are the following: Extremely poor performance on the Nutanix file server. A large amount of lock contention on VDI user profiles/failur...
Currently, this issue has been resolved in Nutanix Files 4.0.1 and above, however, if the customer is using a previous version of Files, the current workaround is the following: allssh 'afs ha.minerva_ha_stop && sleep 60 && cluster start && sleep 60' This command will trigger a restart of all the services on the File ...
KB15509
DRaaS: Redeploying Nutanix On-Prem VPN gateway
How to redeploy VPN gateway on the ON-Prem PC/PE
During Nutanix DRaaS troubleshooting, we may need to redeploy the On-Prem VPN gateway. If it's only a redeployment with no additional changes, follow the procedure in the solution section.
Consult with a DRaaS SME or Xi-SLE team before following this procedure.Below are the step-by-step instructions.1. To force the redeployment in a specific version, set the below gflags in On-Prem PC with the required OCX version and it's checksum.Example below for version 5.0.0e67a8a.20220628 on a PC deployed on AHV cl...
KB12410
Prism Central fails to send rule-based email alerts to the required recipients.
Due to an Out Of Memory crash of the alert_manager service, PCVMs may not send alert emails. This KB documents a workaround until customer can upgrade to version pc.2021.12 or later where the issue has been resolved.
Alert emails may not be sent with the following conditions even though Prism shows the alerts. AOS 6.0 or newer, Prism Central (PC) 2021.5 or newerRule-based alert emails failing to send from PCWorking through KB-6387 http://portal.nutanix.com/kb/6387is successfulIn `dmesg -T` on the Prism Central VMs, we see the fol...
Upgrade Prism Central to a fixed version (pc2021.12 or later) as soon as possible.
KB11087
Importing Config for Palo Alto Firewall does not retain MAC address
Importing Config for Palo Alto Firewall does not retain MAC address
Nutanix Disaster Recovery as a Service (DRaaS) is formerly known as Xi Leap.Customers can deploy a firewall as a VM in XI. This VM can monitor and define policies for inbound/outbound traffic on the Xi cloud. Customers hitting this issue will notice that when they import Onprem Palo Alto's(PA) configuration to a PA VM ...
The MAC address as seen on Virsh needs to be retained when the config is imported. To achieve the above, the below line should be added to the config file downloaded from the Onprem PA, before importing the config to the PA VM on Xi side. <auto-mac-detect>yes</auto-mac-detect>
KB11592
Alert - A130218 - VgAutonomousReplicationDelayed
Investigating VgAutonomousReplicationDelayed issues on a Nutanix cluster
This Nutanix article provides the information required for troubleshooting the alert VgAutonomousReplicationDelayed for your Nutanix cluster.Alert Overview The alert VgAutonomousReplicationDelayed is generated when the replication of the nearsync recovery point is lagging. Sample Alert Block Serial Number: XXXXXXXX...
Troubleshooting and Resolving the issueThe system retries every few minutes to meet the RPO. VgAutonomousReplicationDelayed alerts are auto resolved once the replication catches up.Heavy workload, Network congestion, or any other prevailing network issues in the environment could cause the NearSync replication delay al...
""cluster status\t\t\tcluster start\t\t\tcluster stop"": ""esxcli software vib update --depot /vmfs/volumes///zipfile.zip\t\t\tOr:\t\t\tesxcli software vib update -d /vmfs/volumes///zipfile.zip""
null
null
null
null
KB3284
RMA: Return Instructions (EMEA)
This article shows the printout sent to the customer when a replacement part is requested.
Below is the return instruction letter provided with a replacement part for customers in EMEA region. Nutanix is using DHL for shipments within the European Union. The below instructions are valid only for the European Union. For countries outside of the EU, local couriers might be used with different return instructio...
Instructions for returning the failed device Dear Customer, You have received a replacement part. Please return the defective unit within 1 week from today.This shipment contains replacement parts provided under Nutanix’s Advance Replacement Service. Under the terms and conditions of the RMA policy, the replaced parts ...
KB12355
Converting CentOS servers to Red Hat Enterprise Linux 7 or 8 using the "convert2rhel" tool
Convert2RHEL is a Red Hat-supported utility for conversation of certain Red Hat Enterprise Linux-derivative distributions into a supportable Red Hat Enterprise Linux system.
Convert2RHEL is a tool officially supported by Red Hat for converting certain Red Hat Enterprise Linux (RHEL) derivative distributions, such as CentOS 7 and 8, into a supportable RHEL system. While technical support for the Convert2RHEL tool is provided by Red Hat, Nutanix Support may encounter customers that have use...
Download the Red Hat GPG key to the target VM: [user@centos ~]# curl -o /etc/pki/rpm-gpg/RPM-GPG-KEY-redhat-release https://www.redhat.com/security/data/fd431d51.txt Install the Convert2RHEL repository, replacing VERSION_NUMBER with the appropriate major version of the OS, for example 7 or 8. [user@centos ~]# curl -...
KB12374
Nutanix VirtIO or NGT installation/upgrade may fail due to large amount of Windows VSS snapshots present in a VM
Nutanix VirtIO or Nutanix NGT installation or upgrade may fail if a large amount of Windows VSS snapshots present inside a guest VM
Installation or upgrade of Nutanix VirtIO or Nutanix Guest Tools may fail during installation of "Nutanix VirtIO SCSI pass-through controller" driver if a large amount of Windows VSS snapshots is present in a guest VM with large data disks. In Windows SetupAPI log https://learn.microsoft.com/en-us/windows-hardware/dr...
During the installation of the "Nutanix SCSI pass-through controller" driver, Windows tries to remove the SCSI controller to update the driver. Among the steps, when the controller is removed, there are two items that cause a delay: Dismounting VSS snapshots.Validating their differential areas. In order to workaroun...
KB10450
LCM Troubleshooting: Dark site direct upload (no webserver)
The KB provides you different scenarios where you can observe a failure message when using the "Dark site direct upload (no webserver) method in Prism Element's Life Cycle Manager.
General Information and Limitations: Please refer Life Cycle Manager Dark Site Guide https://portal.nutanix.com/page/documents/details?targetId=Life-Cycle-Manager-Dark-Site-Guide-v2_6:Life-Cycle-Manager-Dark-Site-Guide-v2_6 for understanding the Direct upload method.Currently LCM only supports direct upload for Pris...
3rd Party Bundle: Please note: For ESXi upload Supported ESXi HCI and CO nodesSecure bootMinimum ESXi version is 6.7 Not supported for LCM-2.6 Non NX platformsError message: 10001: 500: Uploaded metadata file validation failed [3rd party upgrades for non-NX platforms are not supported in LCM] We have added me...
KB7732
Unable to join cluster to Prism Central: "Prism Central is unreachable"
When trying to add PE to PC, it may fail with the error "Prism Central is unreachable" despite no network connectivity issue. This article explains how to resolve the issue.
Scenario 1 Joining Prism Element (PE) cluster to Prism Central (PC) may fail with the error message: Prism Central is unreachable Network connectivity between PE and PC is fine, which can be checked using the below commands: Check if port 9440 is open between PE and PC using the command: nutanix@cvm$ nc <prism_c...
Whitelists need to be configured on both Prism Central and its managed clusters. Use the ncli http-proxy add-to-whitelist command to bypass a proxy server used by a managed Prism Element cluster and allow network traffic between Prism Central and the cluster. Previously, if you attempted to register a cluster that impl...
KB4195
Nutanix Files - Delete File Server Forcefully
Deleting the file server forcefully if a graceful way is not working.
In order to delete the File Server instance, Nutanix recommends that you follow the steps updated in the Nutanix Files Setup Guide. https://portal.nutanix.com/page/documents/details?targetId=Files-v4_4:fil-file-server-delete-t.htmlThere can be instances when graceful removal of the file server is not working and you ...
1. Get File Server info for later commands (UUID/Name). nutanix@CVM:~$ ncli fs ls 2. Delete File Protection Domain via Prism. Data Protection > Async DR > NTNX-<Files server> Make sure the 'Schedules' for the Protection Domain is deleted, otherwise the above task will fail. To delete the Schedules, select the Files P...
KB7055
Nutanix Files - Sticky Bit Behavior on NFS distributed exports
This article describes changes to sticky bits introduced in Nutanix Files 3.5.
The sticky bit is a permissions flag that is mainly used on folders. When a folder's sticky bit is set, users can create files and directories in the folder but they can only delete their own files and directories. Without the sticky bit set, any user can delete any other user's files and directories. This is usually s...
Below are the new steps that need to be followed when deleting a top-level directory (TLD) on a home share where SMB is the primary protocol and NFS the secondary: First of all, verify whether the sticky bit is set or not on the home share root. This can be done by running: nutanix@FSVM$ stat <share_root> Or : nu...
KB7287
alert_manager keeps crashing with group_result.raw_results_size() == 1 (2 vs. 1)
Alert Manager service keep crashing and with the message group_result.raw_results_size() == 1 (2 vs. 1) in FATAL logs
Customers might complain that they are receiving the alerts of cluster services crashing repetitively as alert_manager is crashing. When we run "ncli alert ls", we do not see any alerts: nutanix@cvm$ ncli alert ls When checking the FATAL logs we see that it failed with expecting to return 1 value but received 2 fro...
According to ENG-140439 https://jira.nutanix.com/browse/ENG-140439, this was resolved using the below work around: Run allssh pkill alert_manager nutanix@cvm$ allssh pkill alert_manager On one CVM, run the following command: nutanix@cvm$ ~/bin/alert_manager --clear_leader_service_state After 10 minutes, kil...
KB7247
PROBLEM: ssd_repair_status shows "Unable to transfer svmrescue image to host x.x.x.x"
Customer was trying to upgrade SSD capacity of single SSD nodes using "Hardware Replacement Documentation" > "SSD Boot Drive Failure (Single SSD Platforms)" but it fails after clicking "Repair Disk" option in Prism.
NOTE: Also mind ISB-117 since firmware S670330N still contains defects. If the customer is running an older version than S740305N, recommend upgrading. The ssd_repair_status shows "Unable to transfer svmrescue image to host x.x.x.x". nutanix@cvm$ ssd_repair_status The genesis leader log genesis.out shows that the ...
Recover the CVM Create a CVM rescue ISO using this https://confluence.eng.nutanix.com:8443/display/STK/SVM+Rescue%3A+Create+and+Mount procedure.Repair the CVM using this https://confluence.eng.nutanix.com:8443/display/STK/SVM+Rescue%3A+Repairing+a+CVM procedure. Root cause Due to a firmware bug in S560301N, the tr...
KB6141
Stargate fails to initialize cluster-wide due to unresponsive Pithos leader
A Pithos leader could be elected but due to a software defect it doesn't become fully functional. This results in a cluster-wide outage since Stargate can't initialize.
Whenever the current Pithos leader restarts, a new leader will be elected. During ONCALL-4555 we encountered a situation where a new Pithos leader was elected which ended up not being fully functional.This means that all other Pithos processes in the cluster assumed that Pithos on CVM X was the leader but Pithos on CVM...
When the above conditions are met, follow these steps to stop Pithos so another CVM in the cluster can assume Pithos leader role: Collect threads output from Pithos process on the CVM which has the Pithos leader (find this IP by following step 2 in the Description section and look for the leader Handle IP) links --dump...
KB1592
NCC Health Check: cassandra_log_crash_check
The NCC health check cassandra_log_crash_check checks for Cassandra restarts and reports a FAIL status if there were two or more restarts in the last 30 minutes or a WARNING status if there was one restart in the last 5 minutes.
The NCC health check cassandra_log_crash_check verifies if the Cassandra service crashed or restarted recently. This check results in a FAIL status if Cassandra restarted 5 or more times in the last 30 minutes.This check results in a WARN status if Cassandra restarted 3 or more times in the last 5 minutes. NOTE: Thre...
If the NCC check cassandra_log_crash_check returns a FAIL, further investigation is required to determine the reason for the crash. Collecting Additional Information Before collecting additional information, upgrade NCC. For information on upgrading NCC, see KB 2871 https://portal.nutanix.com/kb/2871.Collect the NCC...
KB16234
Prism Central "Create Recovery Point" task fails
Prism Central's "Create Recovery Point" task fails for VMs residing on RF1 containers on the Prism Element cluster.
Disaster Recovery operations like snapshots and replication are not supported for VMs residing in an RF1-enabled storage container. This is notified when the RF1 feature is enabled on the Prism Element (PE) cluster.VMs residing on RF1 containers are also indicated in the Prism Central (PC) "VMs" page, as seen in the sc...
DR operations like snapshot and replication are not supported on VMs in an RF1 storage container. This limitation is documented in KB-11291 https://portal.nutanix.com/kb/11291 - RF1 Guidelines and LimitationsPrism Element Guide. AOS 6.5 guide link https://portal.nutanix.com/page/documents/details?targetId=Web-Consol...
KB12587
NCC Health Check: lenovo-disk-order-check
This KB describes an NCC check which detects certain Lenovo hardware models where the drive mapping on slot 3 and slot 4 drives are swapped.
The NCC Health Check lenovo_disk_order_check validates the drive mapping on certain Lenovo Hardware. Running the NCC CheckRun the check as part of the complete NCC Health Checks: nutanix@cvm$ ncc health_checks run_all Or run this check separately: nutanix@cvm$ ncc health_checks hardware_checks disk_checks lenovo_di...
Detection of the issue : On an affected configuration, the information displayed on PRISM for slots 3 and 4 is swapped. This could result in actions intended for slot 3 to affect slot 4 and vice-versa. When you run list_disk command on the CVM you'll see the issue as the information for drive in Slot 3 and Slot 4 wil...
KB6485
Customizing the Docker Ethernet bridge to avoid IP address conflict in X-Ray
This article describes how to customize the Docker Ethernet bridge to avoid IP address conflict in X-Ray.
When you install Docker, it automatically creates an Ethernet bridge. Containers are automatically connected to the bridge, and traffic to and from the container passes over the bridge to the Docker daemon. By default, Docker uses the IP address range 172.17.0.0/16 for the bridge. This range conflicts with the IP addr...
To avoid this problem, edit the daemon.json file. Find the daemon.json file in /etc/docker. If the file does not exist, create it.Edit the "bip" parameter to set your desired IP address range. For example: { If the file exists and there is existing information inside a square-bracketed section, make sure the bip lin...